For decades, builders and owners have chosen resin floors for their seamless strength. When the base resin is mixed with a reactive hardener, the two react and cure in place.

Although manufacturers use different chemistries to make resin floors, this curing reaction is critical to how they form.

Chemie na střední škole: Osmóza

In osmosis, water moves through a semi-permeable membrane from a more dilute solution toward a more concentrated one. The membrane lets water pass but blocks the dissolved substances, so the concentrations can never even out, and water keeps moving toward the concentrated side.

In a resin floor, the coating itself (or the bond line between the coating and the concrete) can act as that semi-permeable membrane. If water-soluble material is trapped under the coating, moisture from the concrete moves toward it. As water collects in that pocket, the pressure can eventually exceed the coating’s bond to the concrete and push the coating up into a blister.

Think of the concrete as one slice of bread and the resin floor as the other. If something soluble is trapped between the slices, moisture from the bottom slice keeps flowing toward it until the top slice lifts.

"Co se stalo?"

Osmotic blisters are a contractor’s nightmare for two reasons. First (and obviously), they can ruin otherwise good work. Second, too many installers put down resin floors without understanding how much moisture contributes to osmotic blisters.

Apply a resin floor over a concrete slab that still holds too much moisture, and you invite blisters. To prevent them, you first need to understand what causes them.

Stažení zdarma: 4 důvody, proč váš beton schne věčně
Stažení zdarma – 4 důvody, proč váš beton schne věčně

Složení osmotických puchýřů

  1. A semi-permeable membrane: usually the coating itself or the bond interface between the coating and the concrete.
  2. Concentrated water-soluble material (organic or inorganic): the wild card. It can come from resin ingredients in the epoxy coating, residue from acid etching, concrete admixtures, or soluble salts in the concrete.
  3. Water: moisture in the slab, whether it’s left over from the concrete mix or coming up from the ground below.

Přírodní lék

Stones balanced on a seesaw

There’s no simple test that predicts osmotic blisters. However, relative humidity (RH) testing gives installers essential data on concrete readiness. If the slab’s RH is higher than the flooring or coating manufacturer allows, hold off on installing the resin floor.

Preventivní opatření

  • Snažte se minimalizovat množství rozpustných solí v betonové směsi.
  • Pod desku nainstalujte parotěsnou zábranu.
  • Vyhněte se leptání kyselinou jako přípravě povrchu pro nanášení nátěru.
  • Check that the epoxy coating’s components are accurately proportioned and properly mixed.
  • Check the slab’s RH during curing and drying to make sure it’s ready.

Obchod Rapid RH

Naposledy aktualizováno 14. října 2026

2 Komentáře

  1. Terence říká:

    Hledám firmu na pokládku podlah. Mám 8 let zkušeností, ale potřebuji aktuální rady a produkty.

    • Jason Spangler říká:

      Terence:

      Zní to jako vzrušující čas. Hodně štěstí v dobrodružství. S čím konkrétně můžu pomoct?

Napsat komentář

Vaše e-mailová adresa nebude zveřejněna. Povinné položky jsou označeny *